Optical Layout and Mechanical Structure of Polarimeter-Interferometer System for Experimental Advanced Superconducting Tokamak.

Z. Y. Zou,H. Q. Liu,Y. X. Jie,W. X. Ding,D. L. Brower,Z. X. Wang,J. S. Shen,Z. H. An,Y. Yang,L. Zeng,X. C. Wei,G. S. Li,X. Zhu,T. Lan
DOI: https://doi.org/10.1063/1.4890400
IF: 1.6
2014-01-01
Review of Scientific Instruments
Abstract:A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ∼20 m overmoded dielectric waveguide and then divided into 5 horizontal chords. The optical arrangement was designed using ZEMAX, which provides information on the beam spot size and energy distribution throughout the optical system. ZEMAX calculations used to optimize the optical layout design are combined with the mechanical design from CATIA, providing a 3D visualization of the entire POINT system.
What problem does this paper attempt to address?