Abstract:Abstract This study focuses on the feature extraction and classification of surface discharges of ice-covered insulator strings during process of alternating current flashover. The test specimen was the five units suspension ceramic insulators, which was artificially accreted with wet-grown ice in the cold-climate room of CIGELE. Based on the IEEE Standard 1783/2009, flashover experiments were conducted on iced insulators to measure the minimum flashover voltage (VMF) and record the propagating process of surface discharges to flashover by using a high-speed video camera. The gray-level co-occurrence matrix (GLCM) method has been used to extract four parameters of arc discharge images features that characterize different stages of flashover process. The parameters are angular second moment (ASM), contrast (CON), inverse difference moment (IDM) and entropy (ENT). These statistical parameters of GLCM can be extracted to reveal the underlying properties of ice flashover on the insulator surface from the quantitative perspective. The different values of these indicators are representative of the different stages in the process of arc discharge. Once the value of quantitative indicators (ASM, CON, IDM, ENT) of surface discharges exceeds the threshold value, the higher flashover risk of iced insulators will appear. Hence, the proposed methods are helpful to understand and monitor surface discharge on iced outdoor insulator strings for preventing flashover accidents.
multidisciplinary sciences
What problem does this paper attempt to address?
The paper primarily discusses the extraction and classification methods of discharge characteristics on the surface of ice-covered insulator strings during the AC flashover process. The research focuses on analyzing the characteristics of surface discharge images of ice-covered insulator strings during the AC flashover process using the Gray Level Co-occurrence Matrix (GLCM) method. The experiment used five-unit suspension porcelain insulators as test samples, artificially accumulated wet-grown ice in a cold climate chamber, and conducted flashover tests based on IEEE standard 1783/2009, measuring the Minimum Flashover Voltage (VMF) and recording the propagation process of surface discharge to flashover. The paper proposes using the GLCM method to extract four parameters to characterize different stages of the flashover process: Angular Second Moment (ASM), Contrast (CON), Inverse Difference Moment (IDM), and Entropy (ENT). These statistical parameters can reveal the potential attributes of the insulator surface under ice flashover phenomena from a quantitative perspective. When the quantified values of these indicators exceed a threshold, it indicates a higher risk of flashover for ice-covered insulators. Therefore, the proposed method is helpful in understanding and monitoring surface discharge on outdoor ice-covered insulator strings to prevent flashover accidents. Specifically, ASM reflects the homogeneity of the discharge image, with smaller values indicating more uniform discharge; CON measures the local gray level variations in the discharge image, with high values indicating discharge concentrated in specific areas; IDM measures the frequency of occurrence for adjacent pixel pairs, with low values corresponding to locally uneven distribution; ENT describes the randomness of the arc discharge image, with non-uniform images having higher ENT values. By analyzing these parameters, the flashover risk of ice-covered insulators can be effectively predicted, providing strong support for the judgment of insulator accident risks in power systems.