Predistortion Phenomenon of the Field Distortion Switch at High Repetition Frequency

Haoyu Guan,Longkun Hong,Zhigang Liu,Xinxin Wang,Xiaobing Zou
DOI: https://doi.org/10.1109/tps.2024.3371007
IF: 1.368
2024-01-01
IEEE Transactions on Plasma Science
Abstract:The testing experiment on the field distortion switch shows that there is a predistortion phenomenon when it operates under electrical trigger at high repetition frequencies ( $\ge $ 100 Hz), that is, the potential of the trigger electrode is much lower than the expected equipotential surface potential determined by its location during the charging stage, which makes the gap electric field significantly distorted before triggering. This is caused by the distributed capacitance of the switch and the coupling capacitor connected between the trigger circuit and the trigger electrode. The minimum repetition frequency of predistortion is tested to be 10 Hz. Predistortion reduces the maximum operating voltage ( $V_{\mathrm{max}})$ of the switch. $V_{\mathrm{max}}$ of the test switch (static self-breakdown voltage at full insulation recovery is approximately 30 kV) is only 18.04, 17.33, 16.94, and 15.04 kV at repetition frequencies of 100 Hz, 500 Hz, 1 kHz, and 1.3 kHz, respectively, when blowing. In order to restrain the predistortion phenomenon and improve $V_{\mathrm{max}}$ , two methods are proposed: adding a compensation capacitor and adjusting the resistance of gap voltage divider. For the former, $V_{\mathrm{max}}$ can be increased to 28.02, 26.96, 21.85, and 17.06 kV, while for the latter, $V_{\mathrm{max}}$ can be increased to 25.17, 21.81, 17.53, and 16.34 kV, respectively.
physics, fluids & plasmas
What problem does this paper attempt to address?