Design and Performance Analysis of Multi-gap Multi-channel Spark Switch with LCR Triggered Method

ZHANG Zhicheng,ZHANG Xuming,ZHENG Chao,DENG Guanlei,YAN Keping,LIU Zhen
DOI: https://doi.org/10.3969/j.issn.1003-6520.2013.04.024
2013-01-01
Abstract:In order to experimentally research electrical fragmentation of rocks and plasma sterilization,we developed an LCR-triggered,multi-gap,and multi-channel switch.The short pulsed forming switch was formed by the spark switch,of which a group of ceramic capacitors of low inductance in coaxial configuration was charged by a μs primary pulsed power supply.The switch performance was tested with a resistor of 600 Ω,and was further tested by an experiment of sterilization which adopted a pulse power supply.Experimental results showed that the switch had switch-on voltage in range of 29~45 kV while its total gap distance was 14 mm;when the operating voltage was 34 kV,the averaged switch-on time delay and jittering time were 115 μs and 71 μs,respectively.In the test with the resistor,the peak power on the resistor was 1.776 MW,and the range of amplitude and the rise time of the output voltages on the resistor were 33.4~34 kV and 23~28 ns,respectively.The total switch energy loss was 8%,and the energy loss on triggered circuit was 2.163 %.After 2.5×104 shots of switching,the electrode erosion was uniform,and the lengths of the electrodes were unchanged.The output amplitude voltages on the load of continuous 20 times of switching of the spark switch in the presence and absence of LCR triggered circuits were examined.The results show that adopting the LCR triggered circuit has greatly improved the switching stability of the spark switch.