A Low-Jitter Self-Triggered Spark-Discharge Pre-Ionization Switch: Primary Research on Its Breakdown Characteristics and Working Mechanisms

Tianchi Wang,Yingchao Du,Wei Chen,Junna Li,Haiyang Wang,Tao Huang,Linshen Xie,Le Cheng,Ling Shi
DOI: https://doi.org/10.1088/2058-6272/ac2420
2021-01-01
Abstract:MV pulsed switch plays a key role as the transfer switch in large electromagnetic pulse simulators.To broaden the range of self-triggering time,a novel spark-discharge pre-ionization switch,in which the main gap electric field is superposed at the trigger gap to let the electrons in its spark channel also become initial electrons,is proposed and tested.The design idea is:as electrons in the spark channel of the trigger gap always exist after its breakdown,the injection time of pre-ionization should have a more negligible effect on reducing the switch jitter.The experiment results under pulses with a rise time of~100 ns support the above assumptions.When the operating voltage is from~300 to~800 kV and the self-triggering time is~45%to~75%of the peak time,the breakdown time delay jitter is less than 2 ns,and the breakdown voltage jitter is smaller than 1.25%.Under specific self-triggering time,the breakdown time delay jitter is less than 1.5 ns,and the breakdown voltage jitter is smaller than 0.8%.
What problem does this paper attempt to address?