Analysis of performance and cost of a micro-flocculation-D type filter process applied in wastewater tertiary treatment process

Wang Z,Sun Y,Wu G,Wu Q,Hu H,Wu Y,Guo F,Guo Y.
2014-01-01
Abstract:The effluent quality, removal efficiency of total phosphorus (TP), dosages and cost of coagulant of the micro-flocculation-D type filter process in Kunming No. 1 WWTPs were studied. The average TP concentration of the effluent of the process was around 0.15 mg/L with an average removal efficiency of TP of 63.6%. The lowest level of effluent TP concentration of the process was 0.05 mg/L and the 95%-reliably achievable level of it was 0.37 mg/L. The 95%-reliably achievable concentration of suspended solids (SS) of the process was 10 mg/L. The dosage of poly-aluminum chloride (PAC) changed during 1.5~4 mg Al2O3/L, and the average PAC dosage to remove TP was 16.7 mg A2O3/mg-P. The initial Al/P molar ratio was about 2~8, and the effluent TP concentration could be less than or equal to 0.3 mg/L when initial Al/P molar ratio was higher than 5. The average cost of PAC was 0.017 RMB/t.