Analysis of Nitrogen and Phosphorus Removal in A~2O and Inverted A~2O Processes in a Wastewater Treatment Plant

Yuanqiang Guo,Yue Wu,Fang Guo,Zhiping Li
2015-01-01
Abstract:As to the high secondary effluent NO3-N and TP concentrations in A2 O and inverted A2 O processes in a wastewater treatment plant in Kunming,system examination along the treatment stream and batch experiments were carried out to analyze influent and effluent wastewater flow rates and quality and also pollutant dynamics along the treatment stream so as to explore the reasons causing the high effluent. The influent flow rate was very stable while the water quality varied significantly. Both A2 O and inverted A2 O processes removed organic carbon and NH3-N efficiently,with the removal efficiency for organic carbon of 90% and 89. 4% and NH3-N of99. 3% and 98. 6%,respectively. Lack of organic carbon limited denitrification in the A2 O process. In the inverted A2 O process,denitrifiers utilized organic carbon in priority,resulting in a better denitrification efficiency,but in this process,denitrification was affected by dissolved oxygen in the recycling stream. The average sludge retention times( SRT) were up to 27. 6 d and it was very difficult to achieve enhanced biological phosphorus removal by enriching polyphosphate accumulating organisms. Based on the system analysis,SRT below 17 d benefited both nitrogen and phosphorus removal.