Reduction of phosphorous at WWTP combined with DAF and A2/O

Kwon S. B.,Kim D. I.,Guan Y. T.,Dockko S.
DOI: https://doi.org/10.1080/19443994.2014.922447
IF: 1.1
2015-01-01
Desalination and Water Treatment
Abstract:Regulation of the phosphorous (P) concentration in effluent from the Jinju wastewater treatment plant (WWTP) in southern part of Korea has recently been strengthened, with a reduction in the acceptable P limit from 2.0 to 0.2 mg/L. Various treatment processes have been introduced and applied to meet the regulation, after use of biological treatments such as conventional activated sludge, anoxic-oxic (A/O), and anaerobic-anoxic-oxic (A2/O) treatments. The present work introduces a hybrid system of A2/O and dissolved air flotation (DAF) treatment to remove P from the effluent. The total capacity of the WWTP is 190,000 m(3)/d. The dimensions of the DAF basins are 8 m (width), 16 m (length), 4.2 m (height), 6 basins, and the capacity is 2,995 m(3)/d. The retention time and recycling ratio are 19 min and 15%, respectively. The surface loading rate is 240 m/d. Operation of the system with A2/O+DAF has already commenced and total P was reduced from 2.18 to 0.03 mg/L. A2/O+DAF treatment improved the mean effluent concentrations of total phosphorus, chemical oxygen demand, and suspended solids by approximately 70, 29, and 27%, respectively, compared with the corresponding levels in effluent after A2/O treatment alone.