Derivation of Temperature Distribution of Stator Winding with Transposed Conductors for a Large Air-Cooled Hydrogenerator.

Yanping Liang,Ying Wang,Yang Liu,Min Fu
DOI: https://doi.org/10.1109/tie.2016.2554101
IF: 7.7
2016-01-01
IEEE Transactions on Industrial Electronics
Abstract:Calculation of temperature field of transposition strands in slot portion is the key problem in large air-cooled hydrogenerators. With respect to traditional model, the structure of transposition strand is not taken into account, which brings difficulties in reflecting the actual temperature distribution of each strand. To obtain the temperature of each strand, a 250-MW hydrogenerator with 360. transposition strands is taken as the research object. Based on the calculation results of the fluid field in radial ventilation groove, boundary conditions of temperature field model are determined and then the calculation model of stator temperature field is analyzed by finite-volume method (FVM) under a rated load condition. The temperature distribution of each transposition strand is obtained, and the numerical results of model with the transposition strand structure and the baseline model without transposition are compared with tested values, respectively.
What problem does this paper attempt to address?