Failure analysis of spiral finned tube on the economizer

zhiyuan liang,qinxin zhao
DOI: https://doi.org/10.1016/j.engfailanal.2012.10.010
IF: 4
2013-01-01
Engineering Failure Analysis
Abstract:This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-fired power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tithe metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures. (C) 2012 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?