Neutron radiation effects on linear CCDs at different clock pulse frequency

zujun wang,wei chen,benqi tang,zhigang xiao,zhibin yao,baoping he,minbo liu
DOI: https://doi.org/10.1063/1.4922600
IF: 1.697
2015-01-01
AIP Advances
Abstract:The experiments of reactor neutron radiation effects on linear CCDs are presented. The output voltage in dark field after neutron radiation are presented and compared at different clock pulse frequency. The degradation phenomena are analyzed in depth. The mean dark signal (K-D) and dark signal non-uniformity (DSNU) versus neutron fluence is investigated at different clock pulse frequency. The degradation mechanisms of the dark signal and DSNU in linear CCDs are analyzed. The flux of the reactor neutron beams was about 1.33 x 10(8) n/cm(2)/s. The samples were exposed to 1MeV neutron-equivalent fluences of 1 x 10(11), 5 x 10(11), and 1 x 10(12) n/cm(2), respectively. (C) 2015 Author(s).
What problem does this paper attempt to address?