Cryogenic System with GM Cryocooler for Krypton, Xenon Separation from Hydrogen-Helium Purge Gas

X. X. Chu,M. M. Zhang,D. X. Zhang,D. Xu,Y. Qian,W. Liu
DOI: https://doi.org/10.1063/1.4860903
2014-01-01
AIP Conference Proceedings
Abstract:In the thorium molten salt reactor (TMSR), fission products such as krypton, xenon and tritium will be produced continuously in the process of nuclear fission reaction. A cryogenic system with a two stage GM cryocooler was designed to separate Kr, Xe, and H2 from helium purge gas. The temperatures of two stage heat exchanger condensation tanks were maintained at about 38 K and 4.5 K, respectively. The main fluid parameters of heat transfer were confirmed, and the structural heat exchanger equipment and cold box were designed. Designed concentrations after cryogenic separation of Kr, Xe and H2 in helium recycle gas are less than 1 ppb.
What problem does this paper attempt to address?