E211 STAGED SORBENT INJECTION UNDER AIR-STAGED COMBUSTION CONDITIONS FOR SO_2 REDUCTION IN A PULVERIZED COAL FIRED BOILER

Jun Cheng,Xiang Zhao,Hongyu Fan,Xinyu Cao,Zhijun Zhou,Jianzhong Liu,Junhu Zhou,Kefa Cen
DOI: https://doi.org/10.1299/jsmeicope.2003.2._2-399_
2003-01-01
Abstract:In order to promote the SO_2 reduction efficiency from flue gas, the pilot-scale experiments of a staged sorbent injection process combined with air-staged combustion pattern are conducted in a 3.52MW pulverized-coal downshot furnace. It is found that when calcium-based sorbents are simply injected into the upper furnace at Ca/S=2,a low SO_2 reduction efficiency of 26.5% is obtained. When a portion of sorbents are injected by primary air into the combustion zone and others are injected into the upper furnace, the in-furnace desulfurization efficiency is promoted to 41.2% at Ca/S=2 and 71.2% at Ca/S=3.
What problem does this paper attempt to address?