The Performance of A Linear Compressor with Triangle Flexure Bearings

W. J. Zhou,L. Y. Wang,Z. H. Gan,L. M. Qiu,J. M. Pfotenhauer
DOI: https://doi.org/10.1063/1.4707093
2012-01-01
Abstract:This paper reports the performance of a self-fabricated moving coil linear compressor at Zhejiang University. The efficiency of this compressor is tested by an RC load method. From experimental results, its resonant frequency is below 30Hz. When combined with a pulse tube cryocooler (PTC) working at 40Hz, the minimum temperature is 49.1K; the cooling power at 80K is 4.5W, with 540W electricity power input. From the RC load experiment, the maximum efficiency of this compressor is only 37% at 21 Hz. Therefore, this compressor has the potential to drive a three stage PTC at liquid helium temperature by running at 25Hz or lower.