Numerical Study on the Outlet Flow Field of the 300MW Steam Turbine’s Condenser Throat with Flow Guide Devices

Li-hua Cao,Yong Li,Ping-li Huang
DOI: https://doi.org/10.1007/978-3-540-76694-0_81
2007-01-01
Abstract:The low-pressure heaters are laid in the condenser throat to the optimizing introducing 300MW steam turbine made in China, which disposal leads to non-uniformity of the throat outlet flow field and decline of condenser vacuum finally. In this paper, aiming at the problems above, a means of installing flow guide devices under the low-pressure heaters is proposed to improve the uniformity of the throat outlet flow field. In order to analyze the effect of installing flow guide devices, using the κ-ɛ model, the wall-function method and the SIMPLEC algorithm method, the three-dimensional numerical simulation of the throat flow field is carried out. The simulation result shows that because of the influence of the inner low-pressure heaters, the partial high-speed steam flow area, the low speed eddy zone and the low speed area occur in different zone of the throat outlet. However, after the flow guide devices are installed, the distribution of the throat outlet flow field goes to uniformity. Furthermore, practical operation of steam turbine indicates that the condenser vacuum and the economy of operation are improved by installing flow guide devices.