Three-Dimensional Numerical Simulation of the Flow Field in Condenser Throat with Flow Guide Dev

CAO Li-hua,LI Yong,ZHANG Zhong-bin,MENG Fang-qun,CAO Zu-qing
DOI: https://doi.org/10.3321/j.issn:1000-6761.2008.01.024
2008-01-01
Abstract:In allusion to the phenomenon of non-uniform flow field at the throat outlet caused by the low-pressure heaters laid in condenser throat,the flow field inside the condenser throat of 300MW steam turbine was numerically simulated,compared and analyzed before and after the flow guide devices installed by using the model combined with the wall-function method and the SIMPLEC algorithm method.Results indicated that,without the flow guide devices,the flow field at throat outlet was non-uniformity due to the low-pressure heaters installed inside the throat.The distribution of the flow field at the throat outlet trends to uniformity after the flow guide devices installed.The best scheme of installing flow guide devices is given through several numerical simulations.Practical operation of the steam turbine unit indicated that the condenser vacuum is increased and the economy of the unit's operation is improved after the flow guide devices installed.It can meet an objective of energy conservation and dissipation reduction.
What problem does this paper attempt to address?