Analytical Limit Loads for Tube Sections with Circumferential Degradation

W. Reinhardt,X. Wang
DOI: https://doi.org/10.1115/pvp2004-2753
2004-01-01
Abstract:The fracture mechanics evaluation of tubes and pipes with circumferential degradation typically requires that the plastic limit load capacity be evaluated under a combination of axial force and bending moment loading. Most available analytical solutions are thin-wall approximations and may not work well for heavy-wall applications. The present paper derives an analytical limit load for a cylindrical pipe or tube with a partial circumferential, partial through-wall flaw and its bounding cases (through wall partial circumferential and uniform circumferential part-throughwall flaw). The solution is not in closed form, but can be easily solved with available mathematical software like MathCAD. The obtained limit loads for a steam generator tube are compared to those from simplified analytical solutions. The effect of tube supports on the limit load of a tube with non-axisymmetric flaw is discussed with a simplified model.
What problem does this paper attempt to address?