Continuous Operation of 2.45-Ghz Microwave Proton Source for 306 Hours with More Than 50 Ma DC Beam

Peng Shi-Xiang,Zhang Ai-Lin,Ren Hai-Tao,Zhang Tao,Xu Yuan,Zhang Jing-Feng,Gong Jian-Hua
DOI: https://doi.org/10.1088/1674-1056/24/7/075203
2015-01-01
Chinese Physics B
Abstract:This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50–55 m A with energy of 35 ke V has been run for 306 hours continuously. Total beam availability,defined as 35-ke V beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is122 hours.