Electric Field Distribution in 75 Ka Drained Aluminum Reduction Cell

Xiang-peng Li,Jie Li,Yan-qing Lai,Jiang Chen,Zeng-liang Gao,Ye-xiang Liu
DOI: https://doi.org/10.1007/s11771-010-0012-8
2010-01-01
Journal of Central South University of Technology
Abstract:Current distribution in a drained aluminum reduction cell is critical due to its influence on the current efficiency, electrolysis stability, anodes and cathodes integrity. A finite element model was developed to simulate the electric field in a 75 kA drained aluminum reduction cell. The current distribution and influences of the cathode inclination angle and anode-cathode distance (ACD) were studied. The results show that relatively large horizontal current density appears in the aluminum film, and the maximum value reaches 600 kA/m2. As the cathode inclination angle increases from 2° to 15°, the maximum current density of the metal pad increases by 15%, while the maximum current density of the aluminum-wettable coating layer decreases by 27%. The influence of the ACD on the current distribution is not obvious.
What problem does this paper attempt to address?