Influences of various aluminum accumulation sump designs on thermal stress distribution in drained aluminum reduction cell

Xiangpeng Li,Jie Li,Yanqing Lai,LIU Ye-xiang,RAN Yong-hua,Hao Zhou,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:1004-0609.2007.06.023
2007-01-01
The Chinese Journal of Nonferrous Metals
Abstract:In order to optimize the aluminum accumulation sump designs,the characteristics of thermo-stress distribution in the drained style aluminum reduction cells were studied.The electric-thermo-mechanical coupled simulations of two types of drained aluminum reduction cells,i.e.scenario Ⅰ is with central sump and two accessorial sumps at the ends of the cell;scenario Ⅱ is with only a central sump at the cell bottom,were conducted on the commercial finite element method software package ANSYS.The results show that,for scenario Ⅰ,a relatively large thermal stress intensity exists in the carbon cathode,especially for the carbon blocks at the two ends of the cell.For scenario Ⅱ,the aforementioned thermal stress intensity is relieved remarkably,and the deformation is relatively small.