Calculation of Thermal Stress Distribution in Drained Aluminum Reduction Cell Cathode and Its Structural Optimization

刘业翔,李相鹏,李劼,赖延清
DOI: https://doi.org/10.3969/j.issn.1672-7207.2004.06.001
2004-01-01
Abstract:A thermo-stress calculating model of 75 kA drained style aluminum reduction cell was developed with finite element software package ANSYS to calculate thermal stress distribution in the cathode. The results show that when the right angled sump and currently used cathode collector bar were applied, the great stress intensity exists in TiB2 coating layer and the carbon is around the sump. This great stress intensity in the carbon cathode and coating layer is harmful to the integrity of the drained cathode. To decrease the stress intensity in the cathode, cathode structural optimization was put forward, the results show that half circled sump could reduce the stress intensity at the corners of the sump, however there was still anther stress intensity at the bottom of the sump, the maximum values are -6.65 × 107 Pa and -4.97 × 107 Pa in the coating layer and cathode carbon respectively. The sump with the corners rounded serves more effectively to improve the stress distribution in the coating layer and cathode carbon around the sump than that with the right angled corner, and the end rounded cathode bus-bar largely reduces the stress intensity caused by the thermo-expand and deformation.
What problem does this paper attempt to address?