Study on the Quadrature Error under Varying Ambient Pressure for a Bulk Micromachined Z-axis Gyroscope

Jian Cui,Longtao Lin,Zhongyang Guo,Xiaozhu Chi,Qiancheng Zhao,Zhenchuan Yang,Guizhen Yan
DOI: https://doi.org/10.1109/icsict.2008.4735065
2008-01-01
Abstract:This paper focused on the study of the quadrature error for a bulk micromachined gyroscope under varying pressure conditions between 150 Pa and 100 kPa. The source of the quadrature error and the non-ideal model of the micromachined gyroscope are presented with details. The change trend and characterization of pressure dependence were analyzed both analytically and experimentally in the custom-built installation. The results indicated that in order to meet high resolution and stabilization of the quadrature error, the optimal working pressure applied to the gyroscope must limit to a certain boundary condition. At last, some effective methods of restraining the quadrature error were put forward.
What problem does this paper attempt to address?