Research and experiments on niobium-sputtered superconducting QWR in Peking University

Hao, J.K.,Quan, S.W.,Zhao, K.,Zhang, B.C.
DOI: https://doi.org/10.1109/PAC.2001.986616
2001-01-01
Abstract:R&D on SC quarter wave resonators (QWRs) for heavy ion linacs were initiated in China several years ago. A DC bias-voltage sputtering technology was developed in Peking University for niobium-coated copper QWR. A niobium-sputtered copper QWR with good niobium films was successfully made in October 1999. Low temperature experiments were carried out from November 1999 to September 2000. The accelerating gradient of 5~6 MV/m can be obtained with no beam load at 4.2 K. The QWR is installed after the 2×6 MV tandem and is used to accelerate proton beams. The accelerating gradient of 3 MV/m was obtained with a proton beam load
What problem does this paper attempt to address?