Effect of heat-treatment on structure of tungsten coating and ablation properties of C/C-Cu composites

GE Yi-cheng,Ai Ping Liu,Lin Yang,LEI Bao-ling,YI Mao-zhong
2011-01-01
Abstract:Tungsten-coating (W-coating) had been prepared on prepared C/C-Cu composites using plasmatic spraying, the vacuum heat-treatment was carried out at 1400°C for 1 h with a vacuum furnace, and the structure and 30 seconds' ablation-testing using oxyacetylene were investigated. The results show that the W-coating without heat-treatment had been piled by many compressed tungsten particles with some little cracks. The XRD patterns indicated that tungsten is the main phase in the coating. After heat-treatment, many cracks in the coating had been filled with the copper from C/C-Cu matrix, which shows an integrated W-Cu coating but existing a loosed bonding interface between the matrix and the coating due to some cracks and micro-holes. The results of ablated testing shown that the mass loss ratio of the composites without coating was 5.6 mg/s, the coated composites without heat-treatment had good ablation-resistance with a mass loss ratio of 0.9 mg/s, but the coated composites with heat-treatment had the highest mass loss ratio of 12.0 mg/s.
What problem does this paper attempt to address?