The effect of splitters layout at variable cross-section inclined flue on AIG inlet flow field

毛剑宏,蒋新伟,钟毅,宋浩,吴卫红,潘淑萍,高翔,骆仲泱,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973X.2011.08.021
2011-01-01
Abstract:To optimize the velocity distribution of AIG inlet, the design for splitters of variable cross-section flue at the AIG upstream was researched in a coal fire plant selective catalytic reaction(SCR) system. The velocity distribution of AIG upstream with variable cross-section flue was simulated by Fluent software, the effect of uniform splitters installation angle and different installation angle in variable cross-section flue on flow field of AIG inlet was researched and the change of flow field distribution was analyzed. The results show that in the condition of uniform installation angle, the guiding effect of splitters makes the velocity distribution at the two walls perform inverse trends, these two conteracting trends nullify the effect of the splitters and make the Cv value lowest, 15.4% at installation angle of 64°. However, the velocity distribution near two walls at the Z direction is still not uniform. Then a new optimization design method using different installation angle near two walls is put forward, the results show that the optimization design can improve the uniformity of velocity distribution near two walls and makes the Cv value decrease from 15.4% to 12.4%.
What problem does this paper attempt to address?