Analysis and calculation of beam energy spread monitor for HLS LINAC

Jia Fang,B. G. Sun,P. Lu,Qing Luo,Xiaohui Wang
2010-01-01
Abstract:The energy spread measurement using the energy spectrum analysis system at HLS LINAC now is an intercepting measurement which can't measure the real injection beam. To achieve the non-intercepting measurement, a new Beam position monitor (BPM) with eight stripline electrodes in four-axis symmetry is designed, which can measure the energy spread at HLS LINAC in real time. This paper has introduced the physical structure of this new BPM which include eight 20 degree opening angle, 1/4 wavelength (26.2mm) length Stripline electrodes in detail, analyzed and calculated the electrode response and picking up the quadrupole component, and got the theoretical sensitivities of different methods. The BPM is simulated and calculated by CST Microwave Studio Program. The results shows the parameters such as characteristic impedance, electrode coupling degree, time-domain response and frequency-domain response etc are all meet the requirement of HLS LINAC and transfer line.