BPM displacement measurement and prediction at HLS II

Chuhan Wang,Jinkai Lan,Tianyu Zhou,Baogen Sun
DOI: https://doi.org/10.1016/j.nima.2024.169245
2024-03-16
Abstract:Beam orbit stability is a crucial indicator that can be used to evaluate the performance of a synchrotron radiation source. It can be improved through precise orbit measurements with beam position monitors (BPMs) and an appropriate orbit feedback system. A movement of the BPMs pickups directly affects the measurement of the beam orbit, and indirectly affects the beam orbit through the orbit feedback (OFB) system. Two sets of BPM displacement measurement systems (DMS) with nanometer resolution were established at the Hefei Light Source II (HLS II) to measure the BPM displacement and to analyze the related factors. The results showed that the variation in the beam current and the vacuum chamber temperature were correlated with the BPM displacement. By combining the concepts of machine learning with physical principles, a neural network for predicting the BPM displacement was designed and trained, and then expanded to the other, not-measured BPM pickups. When associated with the OFB system, the beam orbit deviation due to BPM displacement could be corrected and the requirements for local beam orbit stability could be satisfied.
physics, particles & fields, nuclear,nuclear science & technology,instruments & instrumentation
What problem does this paper attempt to address?