A study of the preheating temperature of directly buried heat-supply pipelines based on average stress

WANG Fei,WANG Guo-wei,ZOU Ping-hua
2010-01-01
Abstract:When directly buried pipes with large diameter, high temperature and pressure are installed by preheating, serious accidents such as pipeline rupture, compensator fracture will happen in cold water running or during the cooling process. Based on "Average Stress Temperature", preheating temperature is proposed and its function formula is set up on the condition that the heating compressive stress is equivalent to the cooling tensile stress. The curve of "Average Stress Temperature" changed with pressure and diameter is drawn, which can be used to analyze pipeline accidents. Results show that high preheating temperature of large diameter pipes is the main reason for fracture during cooling. When calculating preheating temperature, not only the minimum and maximum cycle temperature, but also the pressure, the diameter and the wall thickness and so on should be considered. The increase of pipeline pressure and diameter plays an important role in reducing "Average Stress Temperature", but has nothing to do with" Intercycle temperature". When all preheating parameters are calculated by using "Average Stress Temperature" instead of "Intercycle temperature", cooling tensile stress for preheated directly buried pipes can be reduced evidently.