Abstract:Due to the shortages in manual method of ultrasonic measurement, such as unreasonable layout of measurement points, inefficiency, instability of measurement accuracy and high labor intensity, an automatic measurement method based on ultrasonic was presented. The procedures of the method were as follows: Related model between angle of incidence and time-domain eigenvalue of reflect wave signal was proposed. Angles between cradle heads and normal direction of measurement point were figured out according to the two associated angles of incidence. Attitude values of mechanical arm at the survey point were gotten by solving motion equation. The feedback error of alignment would decide whether another adjustment course was needed or not. Dynamic water depth was used to judge the trend of surface generally, then transducer attitude was adjusted in order to guarantee enough ultrasonic echo signal, after precise analysis of surface’s curvature, certain measurement points were added to where surface’s curvature changed obviously. The results show that the surveying efficiency and accuracy are high using the method, which proves the method is valid.