Research of surface reconstruction and path generation by ultrasonic inspection

WU Si-yuan,ZHOU Xiao-jun,JIANG Jian,YANG Chen-long
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.05.007
2006-01-01
Abstract:In the ultrasonic inspection of free-form surface component,the probe is difficult to aim at the surface's normal direction and inspection efficiency is low.To solve these problems,a non-isoparametric path generation algorithm was proposed to generate ultrasonic scan path.For the component whose CAD model is unknown,first,profiling measurement based on ultrasonic distance measurement theory was used to measure the component's surface;then B-spline method was applied to restructure of the(component's) surface model;finally,based on the restructured CAD model,a non-isoparametric algorithm is used to generate scan path. This algorithm generates nearly arc-length interval inspection points by using nearly arc-length based parametric redistribution method.Compared with constant parametric path generation methods,this method can generate more efficient inspection paths by reducing the number of scan points,while maintaining inspection precision requirement.It is showed that this method can guarantee ultrasonic incidence direction aiming at the surface's normal direction,and increase inspection accuracy and efficiency.
What problem does this paper attempt to address?