Humidity-temperature Measurement and Drying Characteristics in Multiphase Flow Region of Spray

高继慧,龚泽儒,陈国庆,赵海兵,高建民
DOI: https://doi.org/10.3969/j.issn.1005-9954.2009.06.001
2009-01-01
Abstract:Focusing on the measurement of temperature and humidity in gas-liquid-solid coexisting region,a temperature and humidity measurement device with double gas-pumping loop was designed based on the analysis of several temperature and humidity measurement methods.It was contrasted and optimized through the spray-drying experiment,and the analysis of the distribution characteristic of the temperature and humidity inside drying tower was followed.The results show that there are optimum gas velocities both in inner gas channel and outer gas channel.The inner gas velocity has much more influence on the temperature measurement than the outer gas velocity.When the inner gas velocity is 12-24 m/s,the measured value varies only within 3.3 ℃;when the outer gas velocity is 4-6 m/s,the measured value varies within 1 ℃.The results indicate that the dry-bulb temperature of spray atomization region distributes in the shape of two apexes while humidity distributes in W shape,and the evaporation intensity can reach the max.value at the place spacing 200 mm from the spray nozzle.
What problem does this paper attempt to address?