Measurement of Temperature-Humidity Fields and Characterization of Liquid Phase Distribution in Gas-Liquid Regions

GAO Ji-hui,CHEN Guo-qing,GONG Ze-ru,ZHAO Hai-bing,LIU Jia-xun
DOI: https://doi.org/10.3321/j.issn:1000-6761.2009.11.012
2009-01-01
Abstract:By analyzing the characterization way for flue gas humidity in gas-liquid regions of a spray dryer,a multipoint synchronous data acquisition wet-bulb temperature measuring set was developed to study the measurement of temperature-humidity fields.Results show that within the range of dry-bulb temperature from 90 ℃ to 120 ℃ and wet-bulb temperature from 40 ℃ to 60 ℃,variation of flue gas humidity can be qualitatively characterized by the wet-bulb temperature,which will be kept relatively stable for 30-40s after humidifying performance completed;the closer the humidifying water temperature getting to the wetbulb temperature,the less the measurement error will be;the results of multipoint measurement agree well with that of single-point measurement in both the dense and sparse liquid phase regions;the liquid phase distribution characteristics of measured section can be qualitatively obtained by comparing the temperature of naked thermocouple with that of wet-bulb.
What problem does this paper attempt to address?