AN EXPERIMENTAL STUDY ON HUMIDIFYING PERFORMANCES IN COUNTERCURRENT HUMIDIFIER

王玉璋,翁史烈,李一兴,王永泓
DOI: https://doi.org/10.3321/j.issn:0258-8013.2004.08.030
2004-01-01
Abstract:In order to study in details the humidifying performance of humidifier in HAT cycle, a test system of countercurrent spray humidifier, suitable to study its inner-field using 3D laser PDA, is designed and constructed. The pressure losses, made by the structure of humidifier and the spray field, are measured in this test system. The exit temperatures of air and droplets, the evaporation rate of droplets and the relative humidity along the height of humidifier etc. are investigated under different temperatures, flux and relative humidity of air and different temperatures and flux of water. The influences of inlet parameters of air and water on heating and humidifying of humidifier are analyzed. Some thermocouples used in measuring the temperature of air phase and liquid phase is designed and made. The temperatures of air phase and liquid phase at several positions in the humidifier are measured. It is found in the research that the higher counter flow velocity of the droplets and air, the more helpful in heat and mass transfer, but the high velocity will bring a lot of small droplets into regenerator and combustor where those small droplets absorb heat of high quality that causes a reduction of the efficiency of system. Water temperature rising and to increase the water/gas ration will be helpful in heating and humidifying. Aparting from the nozzle, that temperature difference of water and air will be reduced and in a certain position, both temperature will be lower than that in the inlet air
What problem does this paper attempt to address?