Control and Measurement System for the Tuning of A Pefp Low-Beta Superconducting Rf Cavity

Zhang Liping,Sun An,Yingmin Li,Tang Yazhe,Yong Sub Cho
DOI: https://doi.org/10.3938/jkps.54.2025
2009-01-01
Journal of the Korean Physical Society
Abstract:The superconducting RF (SRF) cavity is being considered to accelerate the proton beam in the proton engineering frontier project (PEFP) linac and for its post-project. lit order to correct; for the frequency shift and the field flatness variation of a TM010 pi mode in a raw PEFP multi-cell (SBF) Cavity caused by manufacturing errors and welding shrinkage during its production, a field flatness timing System has been developed. A new control and measurement system has been successfully developed for the relevant timing system. The system automatically controls the bead's forward movement to a designated position and back to its original point and it also drives the network analyzer to measure and acquire the data oil the SRF cavity while the bead is moving through the SRF cavity. After the bead has past through the cavity. the control and measurement system provides the cavity's field flatness and the timing frequencies of the individual cells. The experiments in this study revealed that the control and measurement system is reliable. By using this control and measurement system, the field flatness of a, PEFP low-beta cavity can be billed from 75-62 % at 697.925 MHz to 1.43 % at 700 MHz, which can satisfy the control requirement.
What problem does this paper attempt to address?