Clock test system for electric energy measuring devices based on GPS

Zhikun Luo,Zhaosheng Teng,Zhenrong Lian,Quan Wan
2009-01-01
Abstract:This article illustrates the development process of a new system, which can measure the clock base frequency and provide GPS synchronous time to calibrate the real-time clock of energy measuring devices. The uncertainty of this test system is analyzed and evaluated. Under current policy of peak-valley tariff, this system provides a safe and effective technical measure for energy measuring administration; this system can also be widely used to test other electronic products that have a precise clock.
What problem does this paper attempt to address?