Effect of stiffener of extended endplate connection on failure mode in fire

Shu-ying HAO,Xiu-ping YANG,bin YAO
2009-01-01
Abstract:In order to reveal the failure mode of extended endplate connections in fire and the effect of compressive stiffener thickness on the fire resistance of connection and the column stability, behaviors of the connection subjected to thermal-mechanically coupling action were investigated. Failure mode of the connection in fire, buckling of compressive stiffener, and the effect of stiffener's thickness on fire resistance and stability of column web were investigated by finite element analysis and theories of steel structure design. The results show that the failure mode of extended endplate connection is the large deformation of bending taking place initially in the tensile zone of endplate and column flange, and then the local buckling of compressive zone in connection causes the loss of carrying load. The thickness of compressive stiffener has significant effects on fire resistance of the connection; thermal stress in the compressive stiffener increases constantly in fire, but the critical stress reduces constantly due to stiffness deterioration of the material, so smaller stiffener thickness buckles the stiffener more easily, which induces the occurring of local buckling for column web and the connection failure. The fire resistance of extended endplate connection and column stability can be improved significantly by applying larger compressive stiffener thickness.
What problem does this paper attempt to address?