Nonlinear Analysis of the Behavior of H-Steel Columns with Different Constraints in Fire

王新堂,郑小尧,丁勇,王雪娇,向志海
DOI: https://doi.org/10.3969/j.issn.2095-0985.2008.04.019
2008-01-01
Journal of Huazhong University of Science and Technology
Abstract:As steel structures play more and more important roles in the constructional engineering,the fire safety problem turned to be an inevitable and significant subject.Thus,it was especially important to carry out the research on the failure mechanism of steel structures in fire.Based upon the assumption that the varying temperature field on the steel component is described in ISO834 temperature curves,and considering the interaction of radiation and convection in fire,the finite element method was used to simulate the temperature field of H-steel column.Then,based on the temperature field,and considering the influence of material nonlinearity and geometric nonlinearity on the thermal response of steel component,the thermal-stress analysis of compressive steel column under the different constraints was carried out.The thermal response of steel components are discussed,including the model of failure,the stresses and displacements of the component with the constraints that the both ends are hinged,and one end hinged and the other restrained axially,respectively.The results show that the enhancement of axial constraint contrarily brings down the ultimate bearing capacity and the critical temperature of the steel column in fire to a certain extent.
What problem does this paper attempt to address?