Analysis of Planar Frame with Steel Beam-Concrete-filled Steel Tubular Columns after Exposure to Complete Fire Process under Different Fire Cases

王景玄,王文达
DOI: https://doi.org/10.14006/j.jzjgxb.2014.03.015
2014-01-01
Abstract:A finite element( FE) model was developed to predict the mechanical behavior of a three-story-three-bay planar frame with concrete-filled steel tubular( CFST) columns after exposure to complete fire process under different fire cases based on multi-scale FE method,considering the steel high-temperature creep and loading at ambient, heating,cooling and post-fire conditions. The FE model was verified by others' experimental results. The deflection of beam and axial deformation of columns were calculated under heating and cooling conditions,respectively. The lateral load P versus lateral displacement Δ relationship of planar frame was simulated after exposure to fire. The results show that the steel high-temperature creep is a part of steel thermal strains and should be considered in the FE model. The frame columns are pushed toward outside due to the thermal expansion of steel beams in heating stage and shrinkage deformation during cooling phase. The beam mid-span sectional deflection is the maximum when fire regions located at three-span in first floor frame and the axial compression deformation of columns is less than the inflation deformation in early heating stage. The bearing capacity and initial stiffness of planar frame are reduced with the fire regions increased.
What problem does this paper attempt to address?