Nonlinear finite element analysis on concrete -filled steel tubular columns during a whole period of fire

Hua Yang,Lin-Hai Han
2006-01-01
Abstract:Finite element method is employed to analyze the behavior of concrete-filled steel tubular (CFST) columns during a whole period of fire. Temperature-load route, used to simulate the real fire action that applied to the CFST columns in a service state, involves four parts, i.e. loading, temperature increasing, temperature decreasing and reloading. A corresponding program is developed, named as NFEACFST. It is found that, in general, temperature-decreasing stage is also important and cannot be ignored. A CFST column, which can resist fire as temperature increasing, may fail in the subsequent temperature-decreasing stage. Typical load-deformation relationship curve of the columns in the whole period of fire is predicted by using the Program NFEACFST. To validate the FE model and the Program, some experimental data published in the past are collected and compared. And the data include fire resistance and residual bearing capacities of the CFST columns at ambient temperature, elevated temperature and after exposure to high temperature. The theoretical results agree with the experimental data well. The work done in this paper provides some references when analyze and design the CFST columns against fire.
What problem does this paper attempt to address?