Effects of sustained axial load and cooling phase on post-fire behaviour of reinforced concrete stub columns

Jingsi Huo,JiaGuang Zhang,Zhiwei Wang,Yan Xiao
DOI: https://doi.org/10.1016/j.firesaf.2013.04.002
IF: 3.78
2013-01-01
Fire Safety Journal
Abstract:In this paper is presented an experimental investigation of the effects of preload and cooling phase on the residual strength, stiffness and ductility of reinforced concrete stub columns which were heated and cooled down to room temperature under sustained axial load. Reinforced concrete stub columns were axially loaded and heated to designed temperatures in a specially built electrical furnace. After the specimens cooled down to ambient temperature with the axial loads kept constant, the stub columns were loaded to failure. The sustained preload led to significant residual deformations of reinforced concrete stub columns during the cooling phase. The test results showed that the mechanical behaviour of the fire-damaged reinforced concrete stub columns with preload was remarkably different from those without preload. The sustained axial loads resulted in obviously increased strength and stiffness during the loading phase, but reduced stiffness and deteriorated ductility in the unloading phase. Based on the test results, it is recommended that the effects of sustained axial loads during the fire and cooling phase should be taken into consideration in assessing the fire-damaged reinforced concrete columns.
What problem does this paper attempt to address?