Harmonic Power Measurement Based on Multi-CPU and a Phase Difference Correction Algorithm

Bo ZENG,Zhaosheng TENG
DOI: https://doi.org/10.3321/j.issn:1000-1026.2009.11.019
2009-01-01
Abstract:When using the fast Fourier transform (FFT) for harmonic analysis and measurement, the measuring accuracy is apt to get affected owing to the spectral leakage The side-lobe characteristics of Rife-Vincent window are studied and a harmonic analysis and harmonic power measurement algorithm based on Rife-Vincent window phase difference correction is proposed. A new-type three-phase harmonic ammeter is designed based on a multi-CPU structure of TDK6513H + ADSP-BF533 + M30624FGPFP, which can accurately measure the electrical harmonic power. Experimental metering outcome indicates that the instrument performance based on the proposed algorithm conforms with the requirements mentioned in GB/T 17833-1999 and GB/T 14549-1993, the errors of the fundamental active power measurement are less than 0.2%, and for the harmonic measurement, errors of amplitudes of harmonic voltage and current in each order are less than 1%, 3%, respectively, the errors of phase difference are less than 2°. The ammeter is suitable for high precision harmonic power measurement. © 2009 State Grid Electric Power Research Institute Press.
What problem does this paper attempt to address?