Harmonic Power Measurement Algorithm Based on Discrete Fourier Series in Asynchronous Sampling

Xiao Yong,Zhao Wei,Huang Songling
DOI: https://doi.org/10.19595/j.cnki.1000-6753.tces.170130
2018-01-01
Abstract:In order to measure the harmonic power, this paper firstly proposes a new algorithm based on discrete Fourier series. The following error analysis presents that under asynchronous sampling, this algorithm cause large harmonic power error, which is proportional to the frequency fluctuation of the electricity grid system. Then this algorithm is optimized by modifying the set of triangular basis functions and adopting the quasi-synchronous iteration method, along with the simplification of the computation. The simulation results reveal that the proposed algorithm can adapt to the ±0.5 Hz fluctuation of the grid frequency and reach the accuracy of 10?6under the steady-state condition. In addition, the harmonic energy measurement maintains higher accuracy than that of the contrast algorithm under the quasi-steady-state condition, validating the effectiveness of the proposed algorithm.
What problem does this paper attempt to address?