A new algorithm for electric energy measurement based on four-order Hanning self-multiplication window triple-spectrum-line interpolation FFT
Liu Tao,Zhuang Shuangyong,Chen Xiaowei,Zhao Wei,Zhang Zhihan,Huang Songling
DOI: https://doi.org/10.3969/j.issn.1001-1390.2017.21.001
2017-01-01
Abstract:In order to further improve the calculation accuracy of the windowed interpolation algorithm,this paper pro-poses a new five-terms cosine window function,four-order Hanning self-multiplication window function,based on this, window function and three spectral lines interpolation correction formula,the general amplitude,phase and frequency interpolation correction formula are derived.We can extract the amplitude,phase and frequency parameters of funda-mental wave and harmonic in the measured voltage and current signal by these general interpolation formulas, and then,we can calculate the electric energy of fundamental wave and harmonic accurately.The simulation results show that,because of the window function has better main lobe and side lobe performance,which can effectively suppress the influence of spectrum leakage and fence effect,so based on this window function,the new algorithm for computing electric energy has higher accuracy.