SHRINKAGE DISTRIBUTION OF CONCRETE WITH ONE SURFACE EXPOSED TO DRY CONDITION

高小建,阚雪峰,杨英姿
DOI: https://doi.org/10.3321/j.issn:0454-5648.2009.01.017
2009-01-01
Abstract:The shrinkage strain of concrete with different water-cement ratios was measured in various depths from the exposed sur- face by using several pairs of fixed sensors.Only one surface of the concrete specimen was exposed to the dry condition during the experiment.The relative humidity change of concrete at various depths from the exposed surface was also studied by using embedded humidity sensors.The results show that the shrinkage and relative humidity reduction are markedly lower in the internal layer(55 mm and 100mm from the surface)than that in the near surface layer(10mm from the surface)of concrete.Such differential distributions of shrinkage strain and relative humidity according to depths from the exposed concrete surface become worse with decreasing water-cement ratio.When one surface of a concrete specimen is exposed to a drying condition,there is a good linear relationship between the shrinkage strain and relative humidity reduction in different depths of concrete.However,the surface layer concrete has a lower shrinkage rate than the internal layer concrete when they reach the same relative humidity.