Experimental study on the thickness of charged dust layer at the back corona breakdown point in electrostatic precipitation

Wangsheng Chen,Xiaodong Xiang,Jidong Lü
2008-01-01
Fresenius environmental bulletin
Abstract:It is quite necessary to determine the thickness of charged dust layer at the back corona breakdown point for selecting the rapping periodicity and the working current in the electrostatic precipitator (ESP) reasonably. For this reason, a wire-plate electrode system with a fly-ash layer covering the plane was presented. The. voltage-current characteristics of the system with the different dust layer thickness were experimentally investigated at 50-150 degrees C. The visual observations had shown that the back discharge on the dust layer always began just below the wire electrode. The craters which were formed by the back corona on the dust layer indicated that the ion wind emitted from the ash layer blew off the dust from the plane electrode. The dust re-entrainment caused by back corona was detrimental to electrostatic performance. It was found that the connection curve of the back corona breakdown points at the different thickness of the fly-ash layer was very smooth and continuous. From this characteristic, a simple graphical method was proposed to determine the dust layer thickness at the back corona breakdown point with the help of the curves of the voltage-current characteristics.
What problem does this paper attempt to address?