Charged Dust Layer Thickness at Back Corona Breakdown Point in Electrostatic Precipitation

CHEN Wang-sheng,XIANG Xiao-dong,LU Ji-dong
DOI: https://doi.org/10.3969/j.issn.1003-6504.2006.10.013
IF: 11.4
2006-01-01
Environmental Science & Technology
Abstract:It is necessary to determine charged dust layer thickness at back corona breakdown point in electrostatic precipitation in order to select rapping periodicity reasonably. A mathematical model of charges and additional electric field in dust layer were developed by electrostatics and a formula for calculating charged dust layer thickness at back corona breakdown point was obtained in accordance with condition equation of back corona breakdown field strength. Results indicated that dust layer thickness is the function of corona current density, dust resistivity, and arrangement of electrodes of electrostatic precipitator. It was found that since the connection line of back corona breakdown points at different thickness became a very smooth and continuous curve, a simple graphical method was proposed to determine dust layer thickness at back corona breakdown point with the help of curves of voltage-current characteristics.
What problem does this paper attempt to address?