Complete linear model for double-inlet pulse tube cooler

Xiao-bin ZHANG,Li-min QIU,Zhi-hua GAN
DOI: https://doi.org/10.3785/j.issn.1008-973X.2008.05.020
2008-01-01
Abstract:A complete linear model was utilized to further understand the refrigeration mechanism of a double-inlet pulse tube cooler, which taking into account of the finite regenerator and reservoir volume. Supposing that the volume flow rate in the regenerator element was proportional to the local pressure gradient, the algebraic formulations of the complete linear model were set up. The expressions of the cooling power, the phase between mass flow rate and pressure as well as the coefficient of performance were presented in the following non-dimensional parameters: The volume ratio of reservoir to pulse tube, the working frequency, the conductance ratio of orifice to regenerator and the conductance ratio of bypass valve to regenerator. The effects of working frequency and the volume ratio of reservoir to pulse tube on the refrigeration performance were analyzed. The optimum operating frequency was obtained, which was identical to the experimental results. Analysis reveals that the phase between mass flow rate and pressure decreased as the conductance ratio of bypass valve to regenerator decreases. The cooler has the maximum cooling power when the working frequency is about 1.4 Hz, and it has the maximum coefficient of performance when the working frequency is about 1.0 Hz.