Reliability analysis on occupant evacuation of elevated metro station in fires

Congling Shi,Maohua Zhong,Zhicheng Liu
2008-01-01
Abstract:The design of occupant evacuation for the elevated metro station should accord with not only Code for Design of Metro, but also the fire engineering safety demand. The paper firstly introduces the reliability analysis method for the design of the evacuation passage of the elevated metro station. Then an elevated metro station of the Guangzhou Line 4 has been taken for the case study. Based on CFD modeling and agent-based evacuation method, the smoke spread and occupant evacuation process have been simulated, indicating the current passage design can assure the safety evacuation in fires. The calculation method can be applied as reference for the passage design of such elevation station.