Performance-based design on occupant evacuation of elevated metro station in fires

Cong-ling SHI,Mao-hua ZHONG,Zhi-cheng LIU,Dong-sheng LIANG,Qin JIANG
DOI: https://doi.org/10.3969/j.issn.1673-193X.2007.04.003
2007-01-01
Abstract:The design of occupant evacuation for the elevated metro station should accord with not only Code for Design of Metro,but also the fire engineering safety demand.The paper firstly introduces the performance-based method for the design of the evacuation passway of the elevated metro station.Then an elevated metro station of the Guangzhou Line 4 have been taken for the case study.Based on CFD modeling and agent-based evacuation method,the smoke spread and occupant evacuation process have been simulated,indicating the current passway design can assure the safety evacuation in fires.The calculation method can been applied as reference for the passway design of such elevation station.
What problem does this paper attempt to address?