Numerical Simulation on Resistance Characteristic of Large Scale Wet Flue Gas Desulphurization Spraying Scrubber

LIN Yong-ming,GAO Xiang,SHI Ping-ping,ZHANG Yong-xin,ZHONG Yi,LUO Zhong-yang,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:0258-8013.2008.05.006
2008-01-01
Abstract:By the Fluent software package, the resistance of 300 MW wet flue gas desulfurization(WFGD) spraying scrubber was simulated, and how different scrubber diameter, level spacing interval, level number, load, ratio of liquid to gas affect the scrubber resistance. The results show, for flue gas flow 125×104 m3/h, scrubber diameter 13 m, four spray levels and level spacing interval 1.7 m, the resistance value of the 300 MW WFGD spraying scrubber is about 950 Pa, which almost accords with the data measured in field. And the scrubber resistance is significantly affected by scrubber diameter, level number, load and ratio of liquid to gas. The simulation results can be provided as the bases for design and operation optimization of the spraying scrubber.
What problem does this paper attempt to address?